Job management software for air conditioning and refrigeration.
One planned service visit to a commercial building, from the booking to the F-Gas record and the invoice.
JB-0431Annual AC service and leak checkIn progress| Task | Photos | Assigned | Completed | |
|---|---|---|---|---|
| VRF‑01Roof plant, 8 indoor units6/6 | ||||
| 1 | Clean indoor unit filters (8) | AM | 14 Oct 2026 | |
| 2 | Clean outdoor coil | AM | 14 Oct 2026 | |
| 3 | Check condensate pumps and drains | AM | 14 Oct 2026 | |
| 4 | Electrical checks | AM | 14 Oct 2026 | |
| 5 | Pressures and temperatures | AM | 14 Oct 2026 | |
| 6 | Leak check, direct method | AM | 14 Oct 2026 | |
| AC‑02Server room split0/4 | ||||
| 7 | Clean filters | AM | — | |
| 8 | Clean coils | — | AM | — |
| 9 | Check condensate drain | — | AM | — |
| 10 | Pressures and temperatures | — | AM | — |
Calder Vale Estates Ltd · 40 Canal Street, Northbridge
Kestrel House has two systems. The page follows both through the visit.
- VRF‑01Roof plant, 8 indoor units14.5 kg of R410A30.276 tonnes CO₂ equivalentLeak check every 12 months
- AC‑02Server room split1.2 kg of R320.81 tonnes CO₂ equivalentNo leak check required
One customer, a site for each building
Each building is a site with its address, who to ask for, how to get in and where to park. The managing agent's payment terms are on the customer.
- Kestrel HouseDefault40 Canal Street, Northbridge NB1 4QT
- Mill Court2 Weir Lane, Northbridge NB2 7HD
- Unit 6 Tannery YardTannery Yard, Eastfield NB6 1LR
- Payment terms
- 30 days
Sets the due date on their invoices
The customerThe Account tab lists the three buildings and holds the 30 days that set the due date on every invoice.
The visit is a job from your service template
The template holds a group of tasks for each system. The appointment on the job tells the customer and the engineer when.
The jobNew job: choose the customer and the template. The job opens with all ten tasks.
A group of tasks for each system
Filters, coils, drains, electrical checks and the leak check are ticked off system by system. A photo is taken on the task it belongs to, with the time and location, and saves without signal.
Calder Vale Estates Ltd · 40 Canal Street, Northbridge
AC‑02 Server room split


14 Oct 2026, 11:05 · time and location saved
Add photos
The F‑Gas record works out the leak check interval
Enter the refrigerant, its GWP and the charge. The record shows the CO₂ equivalent and the statutory interval, and it cannot be issued with a later date of next test.
CO₂eq: 30.276 tonnes · statutory leak check every 12 months
Statutory latest date of next test: 2027-10-14
VRF systemThis job's roof system: 14.5 kg of R410A is 30.276 tonnes, so the leak check is due every 12 months.
A fault found on the visit is quoted before leaving
A failing fan motor is priced on the phone from the price book and emailed. The building manager accepts on the quote's page by typing their name.
Your name and the date are recorded against this quote.
Calder Vale Estates Ltd
40 Canal Street, Northbridge NB1 4QT
Add line
The invoice carries the record and the customer's terms
The due date comes from the customer's 30 days, and their PO number is typed in Reference. The F‑Gas record goes on the invoice's email as a PDF.
| Description | Qty | Amount |
|---|---|---|
| Annual service, VRF system (1 outdoor, 8 indoor units) | 1 | £520.00 |
| Annual service, split system | 1 | £95.00 |
| F-Gas leak check and record, VRF system | 1 | £45.00 |
| Subtotal | £660.00 | |
| VAT | £132.00 | |
| Total | £792.00 | |
Certificates and documents that ride this invoice’s email as PDFs.
FG1FG1-2600041- Reference
- PO 4471902
- Issue date
- 14 Oct 2026
- Due date
- 13 Nov 2026
- 10/11/2026 · Bacs
- £792.00
Xero · Synced as INV-0412
Invoices ›Invoices and payments sync to Xero or QuickBooks ›
Next year's check is on the register
The date of next test shows on the certificates register. A notification is sent before it to the engineer and to everyone who manages certificates.
| Certificate | Ref | Status | Job | Customer | Site | Issued | Next check |
|---|---|---|---|---|---|---|---|
F-Gas Leak Check & Service Record FG1 | FG1-2600041 | Issued | JB-0431 | Calder Vale Estates Ltd | 40 Canal Street, Northbridge | 14 Oct 2026 | 14 Oct 2027 |
F-Gas Leak Check & Service Record FG1 | FG1-2600012 | Issued | JB-0377 | Calder Vale Estates Ltd | 2 Weir Lane, Northbridge | 12 Mar 2026 | 12 Mar 2027 |
F-Gas Leak Check & Service Record FG1 | FG1-2500058 | Due | JB-0298 | Calder Vale Estates Ltd | Tannery Yard, Eastfield | 6 Oct 2025 | 6 Oct 2026 |
F-Gas Leak Check & Service Record FG1-2600041 at 40 Canal Street, Northbridge NB1 4QT is due in 30 days.
One register for every buildingA record reads Due once its date of next test arrives. How long before the date the notification is sent is a setting, from 1 to 30 days.
Also for HVAC and refrigeration firms
Refrigerant Recovery Record ›
Recovered gas gets its own record: the cylinders and weights, the waste carrier and the consignment note number.
A service report for the customer ›
The job report is a PDF of the tasks done and the photos taken, ready to send after the visit.
Heat pump records ›
Design, commissioning, handover and service records for heat pump work.
The customer's appointment page ›
The customer confirms the visit or asks for another time from the link in their email.
Parts bought on the day ›
A part from the wholesaler goes on the job as an expense with a photo of the receipt.
Gas added on a top-up ›
The leak check record takes the gas added, the bottle serial number, and whether it was virgin, recycled or reclaimed.
Try Jobivo free for 14 days.
No card required. Set up in minutes.
Job management software built around HVAC service work
Service work goes back to the same sites and the same systems. Jobivo runs each visit as a job sheet built from your service template, with a group of tasks for each system: filters, coils, drains, electrical checks, pressures and the leak check. Every engineer works the same list on every site. Photos are taken on the task they belong to and carry the time and location.
A customer with several buildings is one customer with a site for each. A site holds its address, the site contact, and notes on access and parking. Quotes are built from your price book and accepted online, and a finished visit is invoiced with the due date set from the customer's payment terms and synced to Xero or QuickBooks. Jobivo also issues F-Gas leak check and refrigerant recovery records. The leak check record shows the CO₂ equivalent of the charge and the statutory interval, and its date of next test appears on the certificates register.
For small HVAC and refrigeration firms
Jobivo is priced per company: Essentials is £29.99 a month, Business is £59.99 and Pro is £99.99. Every plan has unlimited users and unlimited jobs. Essentials covers service job sheets, customer sites, F-Gas records, quotes, invoices and card payments. Business adds the price book, expenses and Xero or QuickBooks, and Pro adds job costing with the margin on each job. The Android and iOS apps are offline-first, so job sheets and photos work on rooftops and in plant rooms with no signal, and sync when you are back in coverage.
Common questions
Can I schedule recurring service visits?
Each visit is a job made from your service template and booked on the calendar. Jobivo does not create repeat visits by itself. The certificates register shows when each system's next leak check is due and sends a notification before the date, so the next visit can be booked.
Can one customer have several buildings?
Yes. A customer can have any number of sites. Each site has its own address, site contact, phone number, and access and parking notes, and a job, quote or invoice is raised against the site it is for.
Does it work on rooftops and in plant rooms with no signal?
Yes. The Android and iOS apps are offline-first. Tasks and photos captured with no signal sync automatically when you are back in coverage.
Does Jobivo handle my F-Gas record keeping?
Jobivo issues the F-Gas Leak Check & Service Record and the Refrigerant Recovery Record. The leak check record shows the CO₂ equivalent of the charge and the statutory leak check interval, and cannot be issued with a later date of next test. Each record is a signed PDF with its own web link. See /certificates/f-gas.
Last updated